    1 Here is the issue: IJ2 creates the initial display of the data with lut converter ranges nondefault (like 13 to 230). But later harmonization is run and IJ2 sets converter range to match IJ1's imp.getDisplayRange() values (0 to 255). This results in data drawing in two different brightnesses. 
     1Here is the issue: IJ2 creates the initial display of the data with lut converter ranges nondefault (like 13 to 230). But later harmonization is run and IJ2 sets converter range to match IJ1's imp.getDisplayRange() values (0 to 255). This change is initiated by assignChannelMinMax() in ColorTableHarmonizer. This results in data drawing in two different brightnesses. 
    22 
    33We want to have one brightness if possible. So try to show image once rather than an initial view and applied updates. Having a way to create a display that is hidden and then updating it while hidden and making visible later would be useful if possible.