Ticket #1619 (closed defect: fixed)

Opened 7 years ago

Last modified 6 years ago

Autocontrast issues with sampling

Reported by: bdezonia Owned by: bdezonia
Priority: major Milestone: imagej2-b8-analysis
Component: Core Version:
Severity: serious Keywords:
Cc: Blocked By:
Blocking: #1244

Description

The Duplicate plugin creates a new image but it's display range settings might not be ideal.

Open Neuron
Duplicate

Created image is much dimmer than its parent.

This might just be another example where we need to do some default auto contrasting code.

Change History

comment:1 Changed 7 years ago by curtis

Why not just clone the display range settings of the parent?

comment:2 Changed 7 years ago by bdezonia

  • Blocking 1358 added

comment:3 Changed 7 years ago by bdezonia

  • Blocking 1244 added; 1358 removed

comment:4 Changed 7 years ago by bdezonia

  • Milestone changed from imagej2-b7-ndim-data to imagej2-b8-analysis

comment:5 Changed 6 years ago by bdezonia

It now does clone the original channels' display ranges on the fix-duplicate-display-range branch. Will merge to master when beta 7 released.

comment:6 Changed 6 years ago by bdezonia

  • Status changed from new to closed
  • Resolution set to fixed

Merged to master. Closing.